»ç¾ç¼(pdf)
|
|
SPA2 IS (Intrinsic Safet - Alarm Trip Monitor Switch ) ´Â Intrinsic Safety certificate (ATEX, IECEx, FMµî)À» ȹµæÇÑ ÇÁ·Î¼¼½º ¾Ë¶÷ ¸ð´ÏÅÍ ½ºÀ§Ä¡·Î¼, À§ÇèÁö¿ª(Hazardous Area, Zone 0, 1) ¿¡¼ µé¾î¿À´Â ÀÔ·Â ½ÅÈ£¸¦ ¹Ù·Î ¿¬°á (Intrinsically Safe Field Connection) ÇÒ ¼ö ÀÖÀ¸¸ç (º»Áú¾ÈÀü), ½ÅÈ£°¡ ¿îÀü ¼³Á¤Ä¡(SP)¸¦ ¹þ¾î³¯ °æ¿ì Alarming ¹× ÇÊ¿ä½Ã Emergency Shutdown µîÀÇ Á¶Ä¡¸¦ ÃëÇϱâ À§ÇÏ¿© »ç¿ëµÇ´Â Alarm Monitor °è±â·Î¼, SIS (Safety Instrumented System) °ú º´ÇàÀ¸·Î »ç¿ëÇÒ ¼ö ÀÖ´Â Hardware type ÀÇ Alarm Monitor Switch ÀÔ´Ï´Ù.
Built-in button ¹× PC programÀ» ÀÌ¿ëÇÏ¿© ¼Õ½±°Ô ÇöÀå¿¡¼ ÇÊ¿äÇÑ ±â´ÉÀ» ¼³Á¤ÇÏ¿© »ç¿ëÇÒ ¼ö ÀÖ´Â Universal Alarm Unit (¹ü¿ë ¾Ë¶÷ À¯´ÏÆ®) ·Î¼, ÃÖ´ë 4 Á¢Á¡Ãú·Â ¹× 1 AO (4-20mA)½ÅÈ£ (Option)¸¦ Ãâ·ÂÇÒ ¼ö ÀÖ°í ¹ü¿ëÀü¿ø½Ã½ºÅÛ (21.6~125Vdc, ¹× 90~260Vac) À» äÅÃÇÏ¿´À¸¸ç, ¸ðµ¨ÅëÀÏ·Î ÀÎÇÑ ÇöÀåÀÇ Àç°í
°¨Ãà ¹× À¯¿¬ÇÑ È£È¯¼ºÀ¸·Î Ç÷£Æ® À¯Áöº¸¼öÀÇ ¿øÈ°¼º±îÁö °í·ÁÇÑ
¾Ë¶÷ ¸ð´ÏÅÍ °è±â ÀÔ´Ï´Ù.
¡á
º»Áú¾ÈÀü¹æÆø ÀÔ·Â (Intrinsic Safety )
¡á ¹ü¿ë ÀÔ·Â(mA,Volt ¿Í T/C, RTD)
¡á 20bit ÀÔ·Â ºÐÇØ´É ¡á Programmable Ãâ·Â(ÃÖ´ë 4 Á¢Á¡ ¹× 4-20mA Option Ãâ·Â) ¡á ¼¾¼Á¡°Ë±â´É
(T/C ¹× RTD¼¾¼ÀÌ»ó) ¡á ¹ü¿ë Àü¿ø (21.6~125Vdc, ¶Ç´Â
90~260Vac version)
»ç ¾ç |
|
|
|
ÀÔ·Â
: |
¡¡ |
HLPRG : 0 - 50mA, 0- 11V Configuration.
TPRG : -50 ~ 1000mV, 0 ~ 4,000 ¿È
T/C:J,K,E,T,R,S,N,B,C
RTD
(2,3,4 Wire):Pt100 (3750, 3850,
3902, 3911, 3916, 3923, 3926,
3928), Ni120, Cu10 ÀÔ·ÂÀúÇ× : 40 ¸Þ°¡¿È |
Ãâ·Â
: |
¡¡ |
SPDT
¸±·¹ÀÌ, 1 form C, 5A @250Vac 50/60Hz or 24Vdc non-inductive.
Option :
AO : 4 - 20mA (1000 ohm)
|
Á¤È®µµ
: |
¡¡ |
±2§Ë,
±1mV, T/C & RTD:±0.1~0.8µµ¾¾AO
option : ±0.01% Cold Junction : ±0.45 µµ¾¾
±âŸ ÀÚ¼¼ÇÑ »çÇ×Àº »ç¾ç¼ ÂüÁ¶
|
Isolation |
|
500Vrms
Case-Input-Output-Power |
Power Comsumption |
|
3.5W typical, 5.5 W maximum
|
ÁÖº¯ ¿Âµµ
: |
¡¡ |
-40 ~ +85 µµ¾¾
|
Ç¥½Ã
ȸé : |
¡¡ |
2x5 14-segmentcharacters, backlit,
Alphanumeric readout accurate to the nearestdigit.
Range: -99999 to 99999;
Decimal point can beuser-set Dual Color LED Alarm Lamp
|
Å©±â
: |
¡¡ |
55
x 100 x 130 mm |
¹«°Ô
: |
¡¡ |
544-601
±×·¥ |
|
|
|
|
|
|
|
À§ÇèÁö¿ª¿¡ À§Ä¡ÇÑ Çʵå°è±â ½ÅÈ£·Î shut down system ¶Ç´Â alram monitoring ÀÌ ÇÊ¿äÇϰųª, ESD ½Ã½ºÅÛ±îÁö´Â ÇÊ¿ä¾ø´Â ¼Ò±Ô¸ð SIS ȯ°æÀÌ ÇÊ¿ä ÇϽʴϱî ? ¶Ç´Â Áß¿äÇÑ ÇÁ·Î¼¼½º°¡ ¼ö½Ã·Î ¼Ë´Ù¿î µÇ½Ê´Ï±î?